Auto Start/Stop System - Disable Voltage method
This prevents the Auto Start/Stop System from activating by requiring a minimum voltage that is higher than factory.
19 - Gateway / Adaptation
- Start/stop start voltage limit : Set to 12 V
- Default value : 7.8 V
No comments to display